| Assessment Year | 2025 |
|---|---|
| Principal Product | socks |
| NAICS | 315110: Hosiery and Sock Mills |
| SIC | 2252: Hosiery, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 98 |
| Plant Area |
127,504
ft2
|
| Annual Production | 1,300,000
units
|
| Production Hrs. Annual | 6,000
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $181,990 | 2,083,704 |
kWh
|
$0.087 | |
| Electricity Demand | $143,432 | 9,168 |
kW-mo/yr
|
$15.64 | |
| Electricity Fees | $19,069 | - |
|
- | |
| Natural Gas | $68,567 | 9,347 |
MMBtu
|
$7.34 | |
| Waste Disposal Costs | |||||
| Water Usage | $6,684 | 358 |
Tgal
|
$18.68 | |
| Water Disposal | $42,924 | 2,617 |
Tgal
|
$16.40 | |
| TOTAL YEARLY COSTS | $462,666 | ||||
| RECOMMENDED SAVINGS* | $212,233 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.8112: Combine utility meters | $71,600 | $480 | - | - | $71,600 | - | |
| 02 | 2.9114: Use solar heat to make electricty | $44,449 | $274,845 |
$44,449
509,147
kWh
|
- | - | - | |
| 03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $35,160 | $35,240 |
$35,160
402,840
kWh
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $27,027 | $5,064 |
$19,894
227,880
kWh
|
$7,133
-
kW-mo/yr
|
- | - | |
| 05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,471 | $600 |
$11,471
131,400
kWh
|
- | - | - | |
| 06 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $7,940 | $3,560 |
$7,940
90,950
kWh
|
- | - | - | |
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $6,809 | $150 |
$6,809
78,000
kWh
|
- | - | - | |
| 08 | 2.3322: Use existing dam to generate electricity | $3,660 | $6,000 |
$3,660
42,000
kWh
|
- | - | - | |
| 09 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,000 | $700 | - | - | - |
$2,000
-
MMBtu
|
|
| 10 | 2.2511: Insulate bare equipment | $1,601 | $199 | - | - | - |
$1,601
-
MMBtu
|
|
| 11 | 2.8121: Apply for tax-free status for energy purchases | $517 | - | - | - | $517 | - | |
| TOTAL RECOMMENDED | $212,233 | $326,838 |
$129,383
1,482,217
kWh
|
$7,133
-
kW-mo/yr
|
$72,117 |
$3,601
-
MMBtu
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs