Assessment Year | 2025 |
---|---|
Principal Product | Door Frames, Door Guides, Seat Hinges, and Belt Molding |
NAICS | 336390: Other Motor Vehicle Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $10 M to 50M |
# of Employees | 205 |
Plant Area |
275,000
ft2
|
Annual Production | 1,642,500
pieces
|
Production Hrs. Annual | 4,000
hrs
|
Location (State) | Georgia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $676,950 | 9,241,376 |
kWh
|
$0.073 | |
Electricity Demand | $1 | 33,174 |
kW-mo/yr
|
$0.000 | |
Natural Gas | $37,400 | 4,744 |
MMBtu
|
$7.88 | |
Waste Disposal Costs | |||||
Water Usage | $2,539 | 837 |
Tgal
|
$3.03 | |
Water Disposal | $4,953 | 837 |
Tgal
|
$5.92 | |
TOTAL YEARLY COSTS | $721,843 | ||||
RECOMMENDED SAVINGS* | $143,104 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.6127: Maintain air filters by cleaning or replacement | $792 | - |
$792
10,817
kWh
|
- | - | |
02 | 2.2511: Insulate bare equipment | $288 | $9 |
$288
3,937
kWh
|
- | - | |
03 | 2.4239: Eliminate or reduce compressed air usage | $14,906 | $2,080 |
$14,906
203,489
kWh
|
- | - | |
04 | 2.2443: Re-use or recycle hot or cold process exhaust air | $10,465 | $3,000 |
$10,465
142,867
kWh
|
- | - | |
05 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,830 | $1,300 |
$3,830
52,293
kWh
|
- | - | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,075 | $400 |
$984
13,428
kWh
|
$91
-
kW-mo/yr
|
- | |
07 | 2.4239: Eliminate or reduce compressed air usage | $18,356 | $7,500 |
$18,356
250,594
kWh
|
- | - | |
08 | 2.6212: Turn off equipment during breaks, reduce operating time | $8,176 | $6,200 |
$8,176
111,624
kWh
|
- | - | |
09 | 4.721: Initiate a program to acquire iso certification | $26,431 | $25,000 |
$25,047
341,931
kWh
|
- |
$1,384
-
MMBtu
|
|
10 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,020 | $1,950 |
$2,020
27,576
kWh
|
- | - | |
11 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $1,519 | $5,000 |
$1,519
20,730
kWh
|
- | - | |
12 | 2.2437: Recover waste heat from equipment | $1,778 | $6,000 | - | - |
$1,778
-
MMBtu
|
|
13 | 2.9114: Use solar heat to make electricty | $53,467 | $386,850 |
$53,467
729,924
kWh
|
- | - | |
TOTAL RECOMMENDED | $143,104 | $445,289 |
$139,850
1,909,211
kWh
|
$91
-
kW-mo/yr
|
$3,162
-
MMBtu
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs