Assessment Year | 2025 |
---|---|
Principal Product | HDPE and PET Containers |
NAICS | 326160: Plastics Bottle Manufacturing |
SIC | 3085: Plastics Bottles |
Sales Range | $10 M to 50M |
# of Employees | 124 |
Plant Area |
141,000
ft2
|
Annual Production | 9,600,000
lb
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $468,780 | 10,639,374 |
kWh
|
$0.044 | |
Electricity Demand | $253,696 | 34,812 |
kW-mo/yr
|
$7.29 | |
Natural Gas | $6,764 | 538 |
MMBtu
|
$12.57 | |
Waste Disposal Costs | |||||
Water Usage | $12,629 | 3,570 |
Tgal
|
$3.54 | |
Water Disposal | $9,633 | 482 |
Tgal
|
$20.00 | |
TOTAL YEARLY COSTS | $751,502 | ||||
RECOMMENDED SAVINGS* | $140,712 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,321 | - |
$3,321
74,296
kWh
|
- | - | - | |
02 | 2.8121: Apply for tax-free status for energy purchases | $1,048 | - | - | - | - | $1,048 | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $998 | $120 |
$998
22,316
kWh
|
- | - | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $2,500 | $550 |
$2,454
54,894
kWh
|
$46
-
kW-mo/yr
|
- | - | |
05 | 2.4239: Eliminate or reduce compressed air usage | $39,392 | $20,000 |
$39,392
881,256
kWh
|
- | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,254 | $1,491 |
$992
22,194
kWh
|
$262
-
kW-mo/yr
|
- | - | |
07 | 4.721: Initiate a program to acquire iso certification | $17,852 | $35,000 |
$17,602
393,657
kWh
|
- |
$250
-
MMBtu
|
- | |
08 | 2.3212: Optimize plant power factor | $8,101 | $31,875 | - | - | - | $8,101 | |
09 | 2.9113: Use solar heat for heat | $66,246 | $798,795 |
$66,246
1,482,015
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $140,712 | $887,831 |
$131,005
2,930,628
kWh
|
$308
-
kW-mo/yr
|
$250
-
MMBtu
|
$9,149 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs