Assessment Year | 2024 |
---|---|
Principal Product | Aluminum door frames |
NAICS | 336370: Motor Vehicle Metal Stamping |
SIC | 3465: Automotive Stampings |
Sales Range | $100 M to 500M |
# of Employees | 297 |
Plant Area |
220,000
ft2
|
Annual Production | 9,120,000
pieces
|
Production Hrs. Annual | 4,625
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $608,406 | 8,577,550 |
kWh
|
$0.071 | |
Electricity Demand | $460,874 | 26,311 |
kW-mo/yr
|
$17.52 | |
Electricity Fees | $(-115,336.0) | - |
|
- | |
Natural Gas | $69,980 | 8,354 |
MMBtu
|
$8.38 | |
Waste Disposal Costs | |||||
Water Usage | $22,434 | 2,738 |
Tgal
|
$8.19 | |
Water Disposal | $20,316 | 2,738 |
Tgal
|
$7.42 | |
TOTAL YEARLY COSTS | $1,066,674 | ||||
RECOMMENDED SAVINGS* | $159,293 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.9113: Use solar heat for heat | $71,296 | $345,600 |
$71,296
1,005,161
kWh
|
- | - | - | - | - | |
02 | 2.3212: Optimize plant power factor | $28,035 | $28,125 | - | - | $28,035 | - | - | - | |
03 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $19,594 | $2,250 |
$11,943
168,372
kWh
|
$7,651
-
kW-mo/yr
|
- | - | - | - | |
04 | 3.4116: Meter recycled water (to reduce sewer charges) | $11,473 | $10,000 | - | - | - | - | - |
$11,473
-
Tgal
|
|
05 | 2.2437: Recover waste heat from equipment | $10,097 | $10,000 | - | - | - |
$10,097
-
MMBtu
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,906 | $3,825 |
$2,990
42,152
kWh
|
$1,916
-
kW-mo/yr
|
- | - | - | - | |
07 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,896 | $1,450 |
$2,984
42,063
kWh
|
$1,912
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,076 | $645 |
$3,076
43,362
kWh
|
- | - | - | - | - | |
09 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,797 | $3,000 |
$1,711
24,129
kWh
|
$86
-
kW-mo/yr
|
- | - | - | - | |
10 | 2.6218: Turn off equipment when not in use | $1,536 | - |
$1,536
21,656
kWh
|
- | - | - | - | - | |
11 | 2.8121: Apply for tax-free status for energy purchases | $1,173 | - | - | - | $1,173 | - | - | - | |
12 | 3.4151: Minimize water usage | $830 | - | - | - | - | - |
$830
-
Tgal
|
- | |
13 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $584 | $1,125 |
$584
8,233
kWh
|
- | - | - | - | - | |
TOTAL RECOMMENDED | $159,293 | $406,020 |
$96,120
1,355,128
kWh
|
$11,565
-
kW-mo/yr
|
$29,208 |
$10,097
-
MMBtu
|
$830
-
Tgal
|
$11,473
-
Tgal
|
||
TOTAL IMPLEMENTED | - | - | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Water Usage Savings | Water Disposal Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs