| Assessment Year | 2024 |
|---|---|
| Principal Product | Metal Fabrication |
| NAICS | 332119: Metal Crown, Closure, and Other Metal Stamping (except Automotive) |
| SIC | 3499: Fabricated Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 53 |
| Plant Area |
125,000
ft2
|
| Annual Production | 17,483,221
units
|
| Production Hrs. Annual | 4,550
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | ||
|---|---|---|---|---|---|
| Electricity Usage | $63,705 | 663,500 |
kWh
|
$0.096 | |
| Electricity Demand | $21,242 | 2,182 |
kW-mo/yr
|
$9.74 | |
| Natural Gas | $14,256 | 1,349 |
MMBtu
|
$10.57 | |
| Waste Disposal Costs | |||||
| Water Usage | $4,692 | 281 |
Tgal
|
$16.68 | |
| Water Disposal | $2,224 | 281 |
Tgal
|
$7.91 | |
| TOTAL YEARLY COSTS | $106,119 | ||||
| RECOMMENDED SAVINGS* | $20,968 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
| IMPLEMENTED SAVINGS* | - | ||||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Water Disposal Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,784 | $3,840 |
$3,774
39,312
kWh
|
$1,010
-
kW-mo/yr
|
- | - | - | |
| 02 | 2.8121: Apply for tax-free status for energy purchases | $4,348 | - | - | - | - | - | $4,348 | |
| 03 | 3.4113: Treat and reuse rinse waters | $3,460 | $1,590 | - | - |
$2,347
-
Tgal
|
$1,113
-
Tgal
|
- | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $3,347 | $2,600 |
$3,347
34,866
kWh
|
- | - | - | - | |
| 05 | 2.7135: Install occupancy sensors | $1,321 | $1,560 |
$1,321
13,764
kWh
|
- | - | - | - | |
| 06 | 2.4231: Reduce the pressure of compressed air to the minimum required | $917 | $113 |
$917
9,555
kWh
|
- | - | - | - | |
| 07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $828 | $840 |
$828
8,620
kWh
|
- | - | - | - | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $819 | $785 |
$819
8,529
kWh
|
- | - | - | - | |
| 09 | 2.7224: Reduce space conditioning during non-working hours | $650 | $100 |
$650
6,773
kWh
|
- | - | - | - | |
| 10 | 2.6212: Turn off equipment during breaks, reduce operating time | $494 | $1,400 |
$494
5,148
kWh
|
- | - | - | - | |
| TOTAL RECOMMENDED | $20,968 | $12,828 |
$12,150
126,567
kWh
|
$1,010
-
kW-mo/yr
|
$2,347
-
Tgal
|
$1,113
-
Tgal
|
$4,348 | ||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Usage Savings | Water Disposal Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs