Assessment Year 2022
Principal Product Heaters and Controls
NAICS 333414: Heating Equipment (except Warm Air Furnaces) Manufacturing
SIC 3433: Heating Equipment, Except Electric and Warm Air Furnaces
Sales Range $50
M
to 100
M
# of Employees 95
Plant Area 141,000
ft2
Annual Production 3,600
pieces
Production Hrs. Annual 4,125
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $126,191 2,233,200
kWh
Electricity Demand $114,688 6,009
kW-mo/yr
Electricity Fees $5,680 -
Natural Gas $44,314 3,445
MMBtu
TOTAL YEARLY COSTS $290,873
RECOMMENDED SAVINGS* $38,947 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings
01 2.2511: Insulate bare equipment $15,235 $8,435 $1,985
35,138
kWh
- - $13,250
-
MMBtu
-
02 4.212: Adopt in-house material generation $11,462 $31,920 $(-425.0)
(-7,522)
kWh
- - - $11,887
03 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $2,904 $3,000 $2,904
51,402
kWh
- - - -
04 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves $2,769 $2,815 $2,769
49,003
kWh
- - - -
05 2.7243: Improve air circulation with destratification fans / other methods $2,371 $4,045 $1,203
21,285
kWh
$1,168
-
kW-mo/yr
- - -
06 2.8114: Change rate schedules or other changes in utility service $2,278 $500 - - $2,278 - -
07 2.7142: Utilize higher efficiency lamps and/or ballasts $1,116 $2,790 $562
9,950
kWh
$554
-
kW-mo/yr
- - -
08 2.4146: Use adjustable frequency drive or multiple speed motors on existing system $812 $1,090 $592
10,477
kWh
$220
-
kW-mo/yr
- - -
TOTAL RECOMMENDED $38,947 $54,595 $9,590
169,732
kWh
$1,942
-
kW-mo/yr
$2,278 $13,250
-
MMBtu
$11,887
TOTAL IMPLEMENTED - - - - - - -
Yearly Savings* Imp'd Cost* Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings Natural Gas Savings Ancillary Material Cost Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs