Assessment Year | 2020 |
---|---|
Principal Product | Porcelain tile |
NAICS | 327120: Clay Building Material and Refractories Manufacturing |
SIC | 3253: Ceramic Wall and Floor Tile |
Sales Range | $50 M to 100M |
# of Employees | 285 |
Plant Area |
1,200,000
ft2
|
Annual Production | 90,000
thousand feet
|
Production Hrs. Annual | 7,728
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $2,802,392 | 51,306,918 |
kWh
|
$0.055 | |
Electricity Demand | $1,267,407 | 190,482 |
kW-mo/yr
|
$6.65 | |
Natural Gas | $2,264,724 | 738,585 |
MMBtu
|
$3.07 | |
Waste Disposal Costs | |||||
Water Usage | $140,128 | 23,456 |
Tgal
|
$5.97 | |
TOTAL YEARLY COSTS | $6,474,651 | ||||
RECOMMENDED SAVINGS* | $531,048 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $301,659 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $294,548 | $574,658 |
$246,867
4,521,357
kWh
|
$47,681
-
kW-mo/yr
|
- | - | |
02 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $84,184 | $2,000 |
$12,364
216,000
kWh
|
$71,820
-
kW-mo/yr
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $63,580 | $248,619 | - | - | - | $63,580 | |
04 | 2.2437: Recover waste heat from equipment | $45,344 | $83,600 | - | - |
$45,344
-
MMBtu
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $36,281 | $7,500 |
$36,281
643,279
kWh
|
- | - | - | |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $7,111 | $600 |
$7,111
130,247
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $531,048 | $916,977 |
$302,623
5,510,883
kWh
|
$119,501
-
kW-mo/yr
|
$45,344
-
MMBtu
|
$63,580 | ||
TOTAL IMPLEMENTED | $301,659 | $575,258 |
$253,978
4,651,604
kWh
|
$47,681
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs