Assessment Year | 2017 |
---|---|
Principal Product | Hydro-static Transmissions and Rear Differentials |
NAICS | 336350: Motor Vehicle Transmission and Power Train Parts Manufacturing |
SIC | 3714: Motor Vehicle Parts and Accessories |
Sales Range | $100 M to 500M |
# of Employees | 190 |
Plant Area |
215,000
ft2
|
Annual Production | 900,000
units
|
Production Hrs. Annual | 6,912
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $528,167 | 8,485,470 |
kWh
|
$0.062 |
Electricity Demand | $240,603 | 19,822 |
kW-mo/yr
|
$12.14 |
Natural Gas | $19,532 | 3,065 |
MMBtu
|
$6.37 |
TOTAL YEARLY COSTS | $788,302 | |||
RECOMMENDED SAVINGS* | $68,984 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $19,605 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9113: Use solar heat for heat | $36,417 | $148,815 |
$36,417
548,000
kWh
|
- | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $19,605 | $3,050 |
$19,605
315,187
kWh
|
- | |
03 | 2.3212: Optimize plant power factor | $5,438 | $19,250 | - |
$5,438
-
kW-mo/yr
|
|
04 | 2.4231: Reduce the pressure of compressed air to the minimum required | $4,985 | $31 |
$3,724
59,817
kWh
|
$1,261
-
kW-mo/yr
|
|
05 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,539 | $1,150 |
$2,539
40,825
kWh
|
- | |
TOTAL RECOMMENDED | $68,984 | $172,296 |
$62,285
963,829
kWh
|
$6,699
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $19,605 | $3,050 |
$19,605
315,187
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs