Assessment Year | 2017 |
---|---|
Principal Product | Food and Aerosol Cans |
NAICS | 332431: Metal Can Manufacturing |
SIC | 3411: Metal Cans |
Sales Range | $100 M to 500M |
# of Employees | 168 |
Plant Area |
325,000
ft2
|
Annual Production | 617,000,000
units
|
Production Hrs. Annual | 6,120
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $490,004 | 13,614,665 |
kWh
|
$0.036 |
Electricity Demand | $376,109 | 27,418 |
kW-mo/yr
|
$13.72 |
Natural Gas | $582,965 | 60,536 |
MMBtu
|
$9.63 |
TOTAL YEARLY COSTS | $1,449,078 | |||
RECOMMENDED SAVINGS* | $61,936 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $26,353 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.4322: Use or replace with energy efficient substitutes | $22,849 | $30,000 |
$(-1,322.0)
(-36,717)
kWh
|
$(-992.0)
-
kW-mo/yr
|
- | $25,163 | |
02 | 2.4239: Eliminate or reduce compressed air usage | $13,441 | $7,000 |
$7,696
213,783
kWh
|
$5,745
-
kW-mo/yr
|
- | - | |
03 | 2.6212: Turn off equipment during breaks, reduce operating time | $11,488 | $5,100 |
$11,488
319,114
kWh
|
- | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,005 | $24,492 |
$5,005
139,031
kWh
|
$2,000
-
kW-mo/yr
|
- | - | |
05 | 2.1233: Analyze flue gas for proper air/fuel ratio | $2,947 | $1,400 | - | - |
$2,947
-
MMBtu
|
- | |
06 | 2.2524: Avoid cooling of process streams or materials that must subsequently be heated | $2,782 | $7,000 | - | - |
$2,782
-
MMBtu
|
- | |
07 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $1,424 | $125 |
$815
22,644
kWh
|
$609
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $61,936 | $75,117 |
$23,682
657,855
kWh
|
$7,362
-
kW-mo/yr
|
$5,729
-
MMBtu
|
$25,163 | ||
TOTAL IMPLEMENTED | $26,353 | $12,225 |
$19,999
555,541
kWh
|
$6,354
-
kW-mo/yr
|
- | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs