Assessment Year | 2014 |
---|---|
Principal Product | Modular Homes |
NAICS | 321991: Manufactured Home (Mobile Home) Manufacturing |
SIC | 2451: Mobile Homes |
Sales Range | $50 M to 100M |
# of Employees | 146 |
Plant Area |
130,000
ft2
|
Annual Production | 4,250
pieces
|
Production Hrs. Annual | 2,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $72,307 | 990,240 |
kWh
|
$0.073 |
Electricity Demand | $44,028 | 4,078 |
kW-mo/yr
|
$10.80 |
Natural Gas | $37,998 | 3,272 |
MMBtu
|
$11.61 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $11,279 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $1,943 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.2135: Repair and eliminate steam leaks | $1,943 | $822 |
$1,943
27,769
kWh
|
- | |
02 | 2.7145: Install skylights | $2,012 | $14,000 |
$2,012
28,753
kWh
|
- | |
03 | 2.7311: Ventilation system to shut off when room is not in use | $1,898 | $24,450 |
$1,898
27,120
kWh
|
- | |
04 | 3.6121: Burn waste paper for heat | $5,426 | $19,895 | - |
$5,426
-
MMBtu
|
|
TOTAL RECOMMENDED | $11,279 | $59,167 |
$5,853
83,642
kWh
|
$5,426
-
MMBtu
|
||
TOTAL IMPLEMENTED | $1,943 | $822 |
$1,943
27,769
kWh
|
- |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs