Assessment Year 2014
Principal Product Modular Homes
NAICS 321991: Manufactured Home (Mobile Home) Manufacturing
SIC 2451: Mobile Homes
Sales Range $50
M
to 100
M
# of Employees 146
Plant Area 130,000
ft2
Annual Production 4,250
pieces
Production Hrs. Annual 2,000
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $72,307 990,240
kWh
Electricity Demand $44,028 4,078
kW-mo/yr
Natural Gas $37,998 3,272
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,279 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $1,943

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.2135: Repair and eliminate steam leaks $1,943 $822 $1,943
27,769
kWh
-
02 2.7145: Install skylights $2,012 $14,000 $2,012
28,753
kWh
-
03 2.7311: Ventilation system to shut off when room is not in use $1,898 $24,450 $1,898
27,120
kWh
-
04 3.6121: Burn waste paper for heat $5,426 $19,895 - $5,426
-
MMBtu
TOTAL RECOMMENDED $11,279 $59,167 $5,853
83,642
kWh
$5,426
-
MMBtu
TOTAL IMPLEMENTED $1,943 $822 $1,943
27,769
kWh
-
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs