Assessment Year | 2012 |
---|---|
Principal Product | Treated Wood-Railroad |
NAICS | 321114: Wood Preservation |
SIC | 2421: Sawmills and Planing Mills, General |
Sales Range | $50 M to 100M |
# of Employees | 100 |
Plant Area |
500,000
ft2
|
Annual Production | 1,000,000
pieces
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Arkansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $279,849 | 3,186,750 |
kWh
|
$0.088 |
Electricity Demand | $36,264 | 10,220 |
kW-mo/yr
|
$3.55 |
Natural Gas | $561,583 | 94,149 |
MMBtu
|
$5.96 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $382,553 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $28,460 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $463 | - |
$463
5,144
kWh
|
- | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $5,193 | $1,753 |
$5,193
57,700
kWh
|
- | |
03 | 2.2135: Repair and eliminate steam leaks | $26,105 | $10,000 | - |
$26,105
-
MMBtu
|
|
04 | 2.4224: Upgrade controls on compressors | $1,892 | $1,000 |
$1,892
21,022
kWh
|
- | |
05 | 2.2614: Use cooling tower or economizer to replace chiller cooling | $18,900 | $2,000 |
$18,900
210,300
kWh
|
- | |
06 | 3.5311: Recover and reuse waste material | $330,000 | $630,000 | - |
$330,000
-
MMBtu
|
|
TOTAL RECOMMENDED | $382,553 | $644,753 |
$26,448
294,166
kWh
|
$356,105
-
MMBtu
|
||
TOTAL IMPLEMENTED | $28,460 | $11,000 |
$2,355
26,166
kWh
|
$26,105
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs