| Assessment Year | 2011 |
|---|---|
| Principal Product | plastics |
| NAICS | 326199: All Other Plastics Product Manufacturing |
| SIC | 3089: Plastics Products, Not Elsewhere Classified |
| Sales Range | less than $500 k |
| # of Employees | 50 |
| Plant Area |
116,640
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 2,340
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $143,337 | 1,170,488 |
kWh
|
$0.12 |
| Electricity Demand | $55,787 | 5,278 |
kW-mo/yr
|
$10.57 |
| Electricity Fees | $12,881 | - |
|
- |
| Natural Gas | $27,251 | 4,388 |
MMBtu
|
$6.21 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $20,117 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $10,803 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,923 | $18,044 |
$6,923
115,439
kWh
|
- | |
| 02 | 2.7135: Install occupancy sensors | $4,602 | $28,092 |
$4,602
76,744
kWh
|
- | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,878 | $11,643 |
$1,878
31,309
kWh
|
- | |
| 04 | 2.4226: Use / purchase optimum sized compressor | $1,256 | $1,480 |
$1,256
20,932
kWh
|
- | |
| 05 | 2.8121: Apply for tax-free status for energy purchases | $1,673 | $15 | - | $1,673 | |
| 06 | 3.6192: Use a less expensive method of waste removal | $2,834 | $1,500 |
$2,834
47,236
kWh
|
- | |
| 07 | 2.5122: Replace high resistance ducts, pipes, and fittings | $952 | $2,625 |
$952
15,869
kWh
|
- | |
| TOTAL RECOMMENDED | $20,117 | $63,399 |
$18,445
307,529
kWh
|
$1,673 | ||
| TOTAL IMPLEMENTED | $10,803 | $22,164 |
$9,131
152,240
kWh
|
$1,673 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs