| Assessment Year | 2011 |
|---|---|
| Principal Product | English Muffins, biscuits, and hearth products |
| NAICS | 311812: Commercial Bakeries |
| SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
| Sales Range | less than $500 k |
| # of Employees | 120 |
| Plant Area |
52,000
ft2
|
| Annual Production | 26,732,172
units
|
| Production Hrs. Annual | 7,280
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $298,139 | 5,149,200 |
kWh
|
$0.058 |
| Electricity Demand | $134,781 | 9,175 |
kW-mo/yr
|
$14.69 |
| Electricity Fees | $(-23,377.4) | - |
|
- |
| Natural Gas | $385,409 | 48,164 |
MMBtu
|
$8.00 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $44,440 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $140 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $7,900 | $7,100 |
$4,200
72,668
kWh
|
$1,500
-
kW-mo/yr
|
- | $2,200 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,500 | $6,200 |
$2,560
44,352
kWh
|
$930
-
kW-mo/yr
|
- | $10 | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,800 | $5,700 |
$1,700
29,786
kWh
|
$600
-
kW-mo/yr
|
- | $500 | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $16,000 | $41,100 |
$10,800
187,488
kWh
|
$3,900
-
kW-mo/yr
|
- | $1,300 | |
| 05 | 2.1213: Direct warmest air to combustion intake | $2,200 | $600 | - | - |
$2,200
-
MMBtu
|
- | |
| 06 | 2.2136: Install / repair insulation on steam lines | $140 | $30 | - | - |
$140
-
MMBtu
|
- | |
| 07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $11,900 | $5,000 |
$9,500
164,200
kWh
|
$2,400
-
kW-mo/yr
|
- | - | |
| TOTAL RECOMMENDED | $44,440 | $65,730 |
$28,760
498,494
kWh
|
$9,330
-
kW-mo/yr
|
$2,340
-
MMBtu
|
$4,010 | ||
| TOTAL IMPLEMENTED | $140 | $30 | - | - |
$140
-
MMBtu
|
- | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs