Assessment Year | 2009 |
---|---|
Principal Product | Hardwood Flooring |
NAICS | 321918: Other Millwork (including Flooring) |
SIC | 2426: Hardwood Dimension and Flooring Mills |
Sales Range | less than $500 k |
# of Employees | 350 |
Plant Area |
80,000
ft2
|
Annual Production | 25,000
thousand feet
|
Production Hrs. Annual | 4,500
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $776,710 | 17,647,764 |
kWh
|
$0.044 |
Electricity Demand | $261,569 | 43,096 |
kW-mo/yr
|
$6.07 |
Electricity Fees | $111,502 | - |
|
- |
Natural Gas | $19,649 | 18,984 |
MMBtu
|
$1.04 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $56,636 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,170 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|---|
01 | 2.6221: Use most efficient equipment at it's maximum capacity and less efficient equipment only when necessary | $17,837 | - |
$14,837
337,209
kWh
|
$3,000
-
kW-mo/yr
|
- | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $15,496 | $57,000 |
$12,026
273,312
kWh
|
$450
-
kW-mo/yr
|
$3,020 | - | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,704 | $7,000 |
$5,304
120,537
kWh
|
$200
-
kW-mo/yr
|
$1,200 | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,906 | $10,250 |
$2,606
59,217
kWh
|
$100
-
kW-mo/yr
|
$1,200 | - | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,681 | $5,100 |
$2,981
67,758
kWh
|
$100
-
kW-mo/yr
|
$600 | - | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,851 | $10,200 |
$1,591
36,161
kWh
|
$60
-
kW-mo/yr
|
$1,200 | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $3,170 | $2,500 |
$3,170
72,054
kWh
|
- | - | - | - | |
08 | 2.4231: Reduce the pressure of compressed air to the minimum required | $1,246 | $800 |
$1,246
28,309
kWh
|
- | - | - | - | |
09 | 2.4322: Use or replace with energy efficient substitutes | $880 | $1,600 | - | - | - | - | $880 | |
10 | 2.2443: Re-use or recycle hot or cold process exhaust air | $865 | $1,730 | - | - | - |
$865
-
MMBtu
|
- | |
TOTAL RECOMMENDED | $56,636 | $96,180 |
$43,761
994,557
kWh
|
$3,910
-
kW-mo/yr
|
$7,220 |
$865
-
MMBtu
|
$880 | ||
TOTAL IMPLEMENTED | $3,170 | $2,500 |
$3,170
72,054
kWh
|
- | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Natural Gas Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs