Assessment Year | 2008 |
---|---|
Principal Product | Automotive Headliners |
NAICS | 336360: Motor Vehicle Seating and Interior Trim Manufacturing |
SIC | 2531: Public Building and Related Furniture |
Sales Range | $50 M to 100M |
# of Employees | 200 |
Plant Area |
125,000
ft2
|
Annual Production | 1,225,000
pieces
|
Production Hrs. Annual | 5,000
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $371,512 | 11,275,500 |
kWh
|
$0.033 |
Electricity Demand | $274,335 | 23,729 |
kW-mo/yr
|
$11.56 |
Electricity Fees | $136,521 | - |
|
- |
Natural Gas | $23,246 | 1,600 |
MMBtu
|
$14.53 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $1,092,473 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $65,250 | $256,400 |
$31,200
843,840
kWh
|
$20,450
-
kW-mo/yr
|
- | $13,600 | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $10,060 | $10,060 |
$4,600
124,848
kWh
|
$3,030
-
kW-mo/yr
|
- | $2,430 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,360 | $12,000 |
$3,000
81,168
kWh
|
$1,960
-
kW-mo/yr
|
- | $1,400 | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,930 | $10,100 |
$2,530
68,352
kWh
|
$1,650
-
kW-mo/yr
|
- | $750 | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $920 | $1,500 |
$250
6,696
kWh
|
$160
-
kW-mo/yr
|
$510 | - | |
06 | 2.3414: Burn waste to produce steam to drive a steam turbine generator set and use steam exhaust for heat | $993,250 | $4,000,000 |
$344,250
9,304,000
kWh
|
$169,000
-
kW-mo/yr
|
- | $480,000 | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $4,100 | $2,500 |
$4,100
336,737
kWh
|
- | - | - | |
08 | 2.4239: Eliminate or reduce compressed air usage | $2,570 | $2,000 |
$2,570
78,846
kWh
|
- | - | - | |
09 | 2.3212: Optimize plant power factor | $5,033 | $23,900 | - | - | $5,033 | - | |
TOTAL RECOMMENDED | $1,092,473 | $4,318,460 |
$392,500
10,844,487
kWh
|
$196,250
-
kW-mo/yr
|
$5,543 | $498,180 | ||
TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs