Assessment Year | 1990 |
---|---|
Principal Product | FIBERGLASS INSULATION |
NAICS |
n/a
|
SIC | 3296: Mineral Wool |
Sales Range | $50 M to 100M |
# of Employees | 375 |
Plant Area |
n/a
|
Annual Production | 98,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Kansas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $2,479,610 | 80,395,077 |
kWh
|
$0.031 |
Natural Gas | $1,611,988 | 855,891 |
MMBtu
|
$1.88 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $128,827 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $81,468 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $76,107 | $149,700 |
$76,107
-
kWh
|
- | |
02 | 2.5194: Redesign process | $27,002 | $15,000 |
$27,002
875,440
kWh
|
- | |
03 | 2.2437: Recover waste heat from equipment | $13,188 | $20,000 | - |
$13,188
-
MMBtu
|
|
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $7,169 | $13,750 |
$7,169
232,415
kWh
|
- | |
05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $4,945 | - |
$4,945
160,317
kWh
|
- | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $416 | $750 |
$416
13,482
kWh
|
- | |
TOTAL RECOMMENDED | $128,827 | $199,200 |
$115,639
1,281,654
kWh
|
$13,188
-
MMBtu
|
||
TOTAL IMPLEMENTED | $81,468 | $150,450 |
$81,468
173,799
kWh
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs