Assessment Year | 2008 |
---|---|
Principal Product | Snack Cakes |
NAICS | 311812: Commercial Bakeries |
SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
Sales Range | less than $500 k |
# of Employees | 200 |
Plant Area |
50,000
ft2
|
Annual Production | 2,250,000
pieces
|
Production Hrs. Annual | 6,000
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $137,261 | 2,974,560 |
kWh
|
$0.046 |
Electricity Demand | $64,619 | 6,918 |
kW-mo/yr
|
$9.34 |
Electricity Fees | $6,684 | - |
|
- |
Natural Gas | $250,000 | 32,042 |
MMBtu
|
$7.80 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $24,931 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $23,298 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
---|---|---|---|---|---|---|---|
01 | 2.3212: Optimize plant power factor | $3,500 | $12,500 | - | $3,500 | - | |
02 | 2.2511: Insulate bare equipment | $520 | $1,700 | - | - |
$520
-
MMBtu
|
|
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,829 | $15,912 |
$2,829
18,398
kWh
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,829 | $15,912 |
$2,829
18,398
kWh
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,957 | $11,633 |
$9,957
101,853
kWh
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $947 | $3,646 |
$947
7,871
kWh
|
- | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $506 | $1,243 |
$506
7,228
kWh
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,508 | $1,641 |
$1,508
18,346
kWh
|
- | - | |
09 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $702 | $263 |
$702
4,036
kWh
|
- | - | |
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,633 | $5,950 |
$1,633
15,503
kWh
|
- | - | |
TOTAL RECOMMENDED | $24,931 | $70,400 |
$20,911
191,633
kWh
|
$3,500 |
$520
-
MMBtu
|
||
TOTAL IMPLEMENTED | $23,298 | $64,450 |
$19,278
176,130
kWh
|
$3,500 |
$520
-
MMBtu
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Fees Savings | Natural Gas Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs