| Assessment Year | 2008 |
|---|---|
| Principal Product | Printed Material |
| NAICS | 323111: Commercial Printing (except Screen and Books) |
| SIC | 2759: Commercial Printing, Not Elsewhere Classified |
| Sales Range | less than $500 k |
| # of Employees | 175 |
| Plant Area |
108,600
ft2
|
| Annual Production | 1
units
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $288,254 | 6,717,750 |
kWh
|
$0.043 |
| Electricity Demand | $151,044 | 13,500 |
kW-mo/yr
|
$11.19 |
| Electricity Fees | $27,508 | - |
|
- |
| Natural Gas | $93,624 | 8,168 |
MMBtu
|
$11.46 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $46,568 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $3,421 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $17,669 | $30,000 |
$17,669
428,857
kWh
|
|
| 02 | 2.7313: Recycle air for heating, ventilation and air conditioning | $7,295 | $10,000 |
$7,295
176,900
kWh
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,586 | $2,000 |
$1,586
72,957
kWh
|
|
| 04 | 2.4235: Remove or close off unneeded compressed air lines | $1,835 | $1,200 |
$1,835
44,557
kWh
|
|
| 05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,183 | $115,288 |
$18,183
504,111
kWh
|
|
| TOTAL RECOMMENDED | $46,568 | $158,488 |
$46,568
1,227,382
kWh
|
||
| TOTAL IMPLEMENTED | $3,421 | $3,200 |
$3,421
117,514
kWh
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs