Assessment Year | 2008 |
---|---|
Principal Product | Non-woven Fabric Treatment |
NAICS | 313320: Fabric Coating Mills |
SIC | 2295: Coated Fabrics, Not Rubberized |
Sales Range | $10 M to 50M |
# of Employees | 83 |
Plant Area |
105,000
ft2
|
Annual Production | 53,750,000
lb
|
Production Hrs. Annual | 7,800
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $253,294 | 5,950,000 |
kWh
|
$0.043 |
Electricity Demand | $133,273 | 10,599 |
kW-mo/yr
|
$12.57 |
Electricity Fees | $12,940 | - |
|
- |
Natural Gas | $1,254,172 | 148,112 |
MMBtu
|
$8.47 |
Fuel Oil #2 | $26,006 | 2,683 |
MMBtu
|
$9.69 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $368,046 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $53,446 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2427: Use waste heat from hot flue gases to preheat incoming fluids | $314,600 | $100,000 | - | - |
$314,600
-
MMBtu
|
- | |
02 | 3.4116: Meter recycled water (to reduce sewer charges) | $33,000 | $1,000 | - | - | - | $33,000 | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $18,809 | $22,423 |
$13,448
314,496
kWh
|
$5,361
-
kW-mo/yr
|
- | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,637 | $5,950 |
$743
17,411
kWh
|
$894
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $368,046 | $129,373 |
$14,191
331,907
kWh
|
$6,255
-
kW-mo/yr
|
$314,600
-
MMBtu
|
$33,000 | ||
TOTAL IMPLEMENTED | $53,446 | $29,373 |
$14,191
331,907
kWh
|
$6,255
-
kW-mo/yr
|
- | $33,000 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs