ITAC Assessment: TR0078
ITAC logo
ITAC Assessment: TR0078
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2026
Principal Product Thermoset molding, electrical breakers
NAICS 326199: All Other Plastics Product Manufacturing
SIC 3089: Plastics Products, Not Elsewhere Classified
Sales Range $10
M
to 50
M
# of Employees 65
Plant Area 38,375
ft2
Annual Production 210,007
pieces
Production Hrs. Annual 6,240
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $191,538 2,908,800
kWh
Electricity Demand $86,621 7,013
kW-mo/yr
Electricity Fees $19,419 -
TOTAL YEARLY COSTS $297,578
RECOMMENDED SAVINGS* $120,974 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.9114: Use solar heat to make electricty $87,931 $287,234 $69,947
1,063,022
kWh
$17,984
-
kW-mo/yr
-
02 2.8121: Apply for tax-free status for energy purchases $17,418 $2,500 - - $17,418
03 2.4322: Use or replace with energy efficient substitutes $6,640 $12,480 $3,097
47,074
kWh
$3,543
-
kW-mo/yr
-
04 2.4322: Use or replace with energy efficient substitutes $8,985 $44,400 $6,603
100,282
kWh
$2,382
-
kW-mo/yr
-
TOTAL RECOMMENDED $120,974 $346,614 $79,648
1,210,378
kWh
$23,908
-
kW-mo/yr
$17,418
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs