| Assessment Year | 2025 |
|---|---|
| Principal Product | 165 |
| NAICS | 326111: Plastics Bag and Pouch Manufacturing |
| SIC | 2673: Plastics, Foil, and Coated Paper Bags |
| Sales Range | $10 M to 50M |
| # of Employees | 165 |
| Plant Area |
60,000
ft2
|
| Annual Production | 8,000,000
pieces
|
| Production Hrs. Annual | 6,160
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $28,794 | 379,064 |
kWh
|
$0.076 |
| Electricity Demand | $12,159 | 963 |
kW-mo/yr
|
$12.62 |
| Electricity Fees | $1,136 | - |
|
- |
| TOTAL YEARLY COSTS | $42,089 | |||
| RECOMMENDED SAVINGS* | $214,788 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $4,011 | $1,887 |
$3,238
42,630
kWh
|
$773
-
kW-mo/yr
|
|
| 02 | 2.4322: Use or replace with energy efficient substitutes | $20,551 | $37,400 |
$16,724
220,124
kWh
|
$3,827
-
kW-mo/yr
|
|
| 03 | 2.4322: Use or replace with energy efficient substitutes | $63,581 | $272,678 |
$45,337
596,860
kWh
|
$18,243
-
kW-mo/yr
|
|
| 04 | 2.9114: Use solar heat to make electricty | $126,645 | $481,160 |
$98,814
1,300,873
kWh
|
$27,831
-
kW-mo/yr
|
|
| TOTAL RECOMMENDED | $214,788 | $793,125 |
$164,114
2,160,487
kWh
|
$50,674
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs