ITAC Assessment: TR0069
ITAC logo
ITAC Assessment: TR0069
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product Gas Main Valves
NAICS 332911: Industrial Valve Manufacturing
SIC 3491: Industrial Valves
Sales Range greater than $500
M
# of Employees 175
Plant Area 49,937
ft2
Annual Production 1,500,000
units
Production Hrs. Annual 4,000
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $104,583 1,899,090
kWh
Electricity Demand $66,192 5,291
kW-mo/yr
Electricity Fees $3,786 -
TOTAL YEARLY COSTS $174,561
RECOMMENDED SAVINGS* $152,557 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings
01 2.4322: Use or replace with energy efficient substitutes $15,890 $37,400 $12,123
220,124
kWh
$3,767
-
kW-mo/yr
02 2.9114: Use solar heat to make electricty $136,380 $662,293 $98,456
1,787,837
kWh
$37,924
-
kW-mo/yr
03 2.7135: Install occupancy sensors $288 $812 $288
5,223
kWh
-
TOTAL RECOMMENDED $152,557 $700,505 $110,866
2,013,184
kWh
$41,691
-
kW-mo/yr
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs