ITAC Assessment: TR0065
ITAC logo
ITAC Assessment: TR0065
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2025
Principal Product water
NAICS 221310: Water Supply and Irrigation Systems
SIC 4952: Sewerage Systems
Sales Range $5
M
to 10
M
# of Employees 14
Plant Area 111,034
ft2
Annual Production 2,920,000
Tgal
Production Hrs. Annual 8,756
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $107,669 1,724,073
kWh
Electricity Demand $58,507 4,679
kW-mo/yr
Electricity Fees $6,547 -
TOTAL YEARLY COSTS $172,723
RECOMMENDED SAVINGS* $150,146 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.9114: Use solar heat to make electricty $138,822 $613,749 $103,715
1,728,580
kWh
$35,107
-
kW-mo/yr
-
02 2.4131: Size electric motors for peak operating efficiency $4,777 $17,300 $3,733
60,896
kWh
$1,044
-
kW-mo/yr
-
03 2.8121: Apply for tax-free status for energy purchases $6,547 $2,500 - - $6,547
TOTAL RECOMMENDED $150,146 $633,549 $107,448
1,789,476
kWh
$36,151
-
kW-mo/yr
$6,547
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs