ITAC Assessment: TR0055
ITAC logo
ITAC Assessment: TR0055
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 2024
Principal Product Treat wastewater
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $5
M
to 10
M
# of Employees 19
Plant Area 2,119,989
ft2
Annual Production 3,467,500
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $86,187 2,267,020
kWh
Electricity Demand $44,845 4,602
kW-mo/yr
Electricity Fees $15,314 -
TOTAL YEARLY COSTS $146,346
RECOMMENDED SAVINGS* $42,273 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.9114: Use solar heat to make electricty $39,213 $191,076 $28,450
768,930
kWh
$10,763
-
kW-mo/yr
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $128 $466 $95
2,497
kWh
$33
-
kW-mo/yr
-
03 2.8121: Apply for tax-free status for energy purchases $2,932 $2,500 - - $2,932
TOTAL RECOMMENDED $42,273 $194,042 $28,545
771,427
kWh
$10,796
-
kW-mo/yr
$2,932
TOTAL IMPLEMENTED - - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs