Assessment Year | 2024 |
---|---|
Principal Product | Treat wastewater |
NAICS | 221320: Sewage Treatment Facilities |
SIC | 4952: Sewerage Systems |
Sales Range | $5 M to 10M |
# of Employees | 19 |
Plant Area |
2,119,989
ft2
|
Annual Production | 3,467,500
Tgal
|
Production Hrs. Annual | 8,760
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $86,187 | 2,267,020 |
kWh
|
$0.038 |
Electricity Demand | $44,845 | 4,602 |
kW-mo/yr
|
$9.74 |
Electricity Fees | $15,314 | - |
|
- |
TOTAL YEARLY COSTS | $146,346 | |||
RECOMMENDED SAVINGS* | $42,273 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings |
---|---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $39,213 | $191,076 |
$28,450
768,930
kWh
|
$10,763
-
kW-mo/yr
|
- | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $128 | $466 |
$95
2,497
kWh
|
$33
-
kW-mo/yr
|
- | |
03 | 2.8121: Apply for tax-free status for energy purchases | $2,932 | $2,500 | - | - | $2,932 | |
TOTAL RECOMMENDED | $42,273 | $194,042 |
$28,545
771,427
kWh
|
$10,796
-
kW-mo/yr
|
$2,932 | ||
TOTAL IMPLEMENTED | - | - | - | - | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs