Assessment Year 2024
Principal Product Treat wastewater
NAICS 221320: Sewage Treatment Facilities
SIC 4952: Sewerage Systems
Sales Range $5
M
to 10
M
# of Employees 19
Plant Area 2,831,000
ft2
Annual Production 3,467,500
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $313,927 8,442,800
kWh
Electricity Demand $136,664 15,517
kW-mo/yr
Electricity Fees $91,893 -
TOTAL YEARLY COSTS $542,484
RECOMMENDED SAVINGS* $125,900 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Electricity Demand Savings Electricity Fees Savings
01 2.9114: Use solar heat to make electricty $104,742 $1,421,000 $72,046
1,937,627
kWh
$32,696
-
kW-mo/yr
-
02 2.4131: Size electric motors for peak operating efficiency $10,236 $21,298 $7,734
208,023
kWh
$2,502
-
kW-mo/yr
-
03 2.8121: Apply for tax-free status for energy purchases $10,922 $2,500 - - $10,922
TOTAL RECOMMENDED $125,900 $1,444,798 $79,781
2,145,650
kWh
$35,198
-
kW-mo/yr
$10,922
TOTAL IMPLEMENTED - - - - -