Assessment Year | 2023 |
---|---|
Principal Product | Drinking water |
NAICS | 221310: Water Supply and Irrigation Systems |
SIC | 4941: Water Supply |
Sales Range | $10 M to 50M |
# of Employees | 34 |
Plant Area |
507,959
ft2
|
Annual Production | 9,125
Tgal
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $320,451 | 7,660,800 |
kWh
|
$0.042 |
Electricity Demand | $167,257 | 19,018 |
kW-mo/yr
|
$8.79 |
Electricity Fees | $34,441 | - |
|
- |
TOTAL YEARLY COSTS | $522,149 | |||
RECOMMENDED SAVINGS* | $70,375 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $34,070 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Water Usage Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.7232: Replace existing hvac unit with high efficiency model | $31,116 | $50,670 |
$6,983
166,938
kWh
|
$24,133
-
kW-mo/yr
|
- | - | |
02 | 3.8121: Cover containers to minimize evaporative losses | $5,133 | $79,969 | - | - | - |
$5,133
-
Tgal
|
|
03 | 2.8121: Apply for tax-free status for energy purchases | $22,602 | $2,500 | - | - | $22,602 | - | |
04 | 2.4131: Size electric motors for peak operating efficiency | $11,468 | $36,208 |
$8,904
212,861
kWh
|
$2,564
-
kW-mo/yr
|
- | - | |
05 | 2.7423: Reduce heat gain by window tinting | $56 | $846 |
$30
724
kWh
|
$26
-
kW-mo/yr
|
- | - | |
TOTAL RECOMMENDED | $70,375 | $170,192 |
$15,917
380,523
kWh
|
$26,724
-
kW-mo/yr
|
$22,602 |
$5,133
-
Tgal
|
||
TOTAL IMPLEMENTED | $34,070 | $38,708 |
$8,904
212,861
kWh
|
$2,564
-
kW-mo/yr
|
$22,602 | - |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs