| Assessment Year | 2023 |
|---|---|
| Principal Product | Ferrous (P&S, HMS, Shr'd), non Ferrous (Zorbu, mix metals) |
| NAICS | 423930: Recyclable Material Merchant Wholesalers |
| SIC | 3399: Primary Metal Products, Not Elsewhere Classified |
| Sales Range | $10 M to 50M |
| # of Employees | 219 |
| Plant Area |
2,918,520
ft2
|
| Annual Production | 57,294
ton
|
| Production Hrs. Annual | 2,432
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $83,430 | 734,600 |
kWh
|
$0.11 |
| Electricity Demand | $67,752 | 21,072 |
kW-mo/yr
|
$3.22 |
| Electricity Fees | $3,831 | - |
|
- |
| TOTAL YEARLY COSTS | $155,013 | |||
| RECOMMENDED SAVINGS* | $301,297 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $3,606 | $6,302 |
$3,164
27,859
kWh
|
$442
-
kW-mo/yr
|
|
| 02 | 2.3212: Optimize plant power factor | $6,520 | $17,100 | - |
$6,520
-
kW-mo/yr
|
|
| 03 | 2.9114: Use solar heat to make electricty | $291,171 | $4,331,813 |
$291,171
6,409,400
kWh
|
- | |
| TOTAL RECOMMENDED | $301,297 | $4,355,215 |
$294,335
6,437,259
kWh
|
$6,962
-
kW-mo/yr
|
||
| TOTAL IMPLEMENTED | - | - | - | - | ||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs