Assessment Year | 2022 |
---|---|
Principal Product | Produce |
NAICS | 311999: All Other Miscellaneous Food Manufacturing |
SIC | 2099: Food Preparations, Not Elsewhere Classified |
Sales Range | $1 M to 5M |
# of Employees | 45 |
Plant Area |
50,000
ft2
|
Annual Production | 75,000
units
|
Production Hrs. Annual | 4,368
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $78,168 | 1,425,600 |
kWh
|
$0.055 | |
Electricity Demand | $47,440 | 4,236 |
kW-mo/yr
|
$11.20 | |
Electricity Fees | $12,883 | - |
|
- | |
Waste Disposal Costs | |||||
Water Usage | $21,337 | 4,969 |
Tgal
|
$4.29 | |
TOTAL YEARLY COSTS | $159,828 | ||||
RECOMMENDED SAVINGS* | $23,117 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $23,117 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.9114: Use solar heat to make electricty | $13,094 | $200,200 |
$8,184
148,000
kWh
|
$4,910
-
kW-mo/yr
|
|
02 | 2.7135: Install occupancy sensors | $133 | $195 |
$133
2,422
kWh
|
- | |
03 | 2.3191: Use demand controller or load shedder | $6,145 | $7,000 | - |
$6,145
-
kW-mo/yr
|
|
04 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $3,744 | $7,758 |
$3,744
68,078
kWh
|
- | |
TOTAL RECOMMENDED | $23,117 | $215,153 |
$12,061
218,499
kWh
|
$11,055
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | $23,117 | $215,153 |
$12,061
218,499
kWh
|
$11,055
-
kW-mo/yr
|
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs