Assessment Year | 2020 |
---|---|
Principal Product | Gas main valves |
NAICS | 332911: Industrial Valve Manufacturing |
SIC | 3491: Industrial Valves |
Sales Range | greater than $500 M |
# of Employees | 280 |
Plant Area |
49,937
ft2
|
Annual Production | 30,000,000
units
|
Production Hrs. Annual | 4,680
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $102,466 | 1,747,440 |
kWh
|
$0.059 | |
Electricity Demand | $56,647 | 5,506 |
kW-mo/yr
|
$10.29 | |
Electricity Fees | $15,273 | - |
|
- | |
Natural Gas | $6,612 | 5,863 |
MMBtu
|
$1.13 | |
Waste Disposal Costs | |||||
Water Usage | $9,474 | 693 |
Tgal
|
$13.67 | |
TOTAL YEARLY COSTS | $190,472 | ||||
RECOMMENDED SAVINGS* | $30,652 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $17,623 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3132: Recharge batteries on during off-peak demand periods | $1,078 | - | - |
$1,078
-
kW-mo/yr
|
- | - | |
02 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,125 | $1,000 |
$776
13,234
kWh
|
$349
-
kW-mo/yr
|
- | - | |
03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $8,666 | $10,056 |
$5,975
101,970
kWh
|
$2,691
-
kW-mo/yr
|
- | - | |
04 | 2.7212: Install or upgrade insulation on hvac distribution systems | $204 | $102 |
$140
2,396
kWh
|
$63
-
kW-mo/yr
|
- | - | |
05 | 2.8121: Apply for tax-free status for energy purchases | $11,951 | $15,000 | - | - | $11,951 | - | |
06 | 3.6192: Use a less expensive method of waste removal | $7,628 | - | - | - | - | $7,628 | |
TOTAL RECOMMENDED | $30,652 | $26,158 |
$6,891
117,599
kWh
|
$4,181
-
kW-mo/yr
|
$11,951 | $7,628 | ||
TOTAL IMPLEMENTED | $17,623 | $11,158 |
$6,891
117,599
kWh
|
$3,103
-
kW-mo/yr
|
- | $7,628 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs