| Assessment Year | 2019 |
|---|---|
| Principal Product | Water |
| NAICS | 221310: Water Supply and Irrigation Systems |
| SIC | 4941: Water Supply |
| Sales Range | $10 M to 50M |
| # of Employees | 10 |
| Plant Area |
1,546,380
ft2
|
| Annual Production | 1,830,000
Tgal
|
| Production Hrs. Annual | 8,760
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $112,735 | 1,513,920 |
kWh
|
$0.074 |
| Electricity Demand | $14,263 | 3,566 |
kW-mo/yr
|
$4.00 |
| Electricity Fees | $1,020 | - |
|
- |
| TOTAL YEARLY COSTS | $128,018 | |||
| RECOMMENDED SAVINGS* | $580,729 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $8,851 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Water Usage Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $2,354 | $4,519 |
$2,354
28,054
kWh
|
- | - | - | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,876 | $1,778 |
$1,876
22,356
kWh
|
- | - | - | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,445 | - |
$1,445
17,222
kWh
|
- | - | - | |
| 04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $959 | $225 |
$423
5,046
kWh
|
- | $273 | $263 | |
| 05 | 3.7311: Maintain machines to reduce leaks | $1,751 | $1,351 | - |
$1,751
-
Tgal
|
- | - | |
| 06 | 3.8121: Cover containers to minimize evaporative losses | $466,053 | $1,043,438 | - |
$466,053
-
Tgal
|
- | - | |
| 07 | 2.7423: Reduce heat gain by window tinting | $1,426 | $1,320 |
$1,426
16,994
kWh
|
- | - | - | |
| 08 | 2.9114: Use solar heat to make electricty | $104,866 | $89,113 |
$104,866
1,249,894
kWh
|
- | - | - | |
| TOTAL RECOMMENDED | $580,729 | $1,141,744 |
$112,389
1,339,565
kWh
|
$467,804
-
Tgal
|
$273 | $263 | ||
| TOTAL IMPLEMENTED | $8,851 | $8,968 |
$7,100
84,625
kWh
|
$1,751
-
Tgal
|
- | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Water Usage Savings | Primary Raw Material Savings | Ancillary Material Cost Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs