Assessment Year | 1997 |
---|---|
Principal Product | surgical cameras |
NAICS |
n/a
|
SIC | 3842: Orthopedic, Prosthetic, and Surgical Appliances and Supplies |
Sales Range | $10 M to 50M |
# of Employees | 0 |
Plant Area |
60,000
ft2
|
Annual Production | 14,400
pieces
|
Production Hrs. Annual | 2,470
hrs
|
Location (State) | Oklahoma |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $23,196 | 791,618 |
kWh
|
$0.029 |
Electricity Demand | $24,514 | 2,182 |
kW-mo/yr
|
$11.23 |
Electricity Fees | $876 | - |
|
- |
Natural Gas | $4,807 | 846 |
MMBtu
|
$5.68 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $8,291 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $2,788 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.6232: Install set-back timers | $2,215 | $3,472 | - |
$2,215
-
MMBtu
|
- | - | |
02 | 3.6192: Use a less expensive method of waste removal | $5,088 | - | - | - |
$5,088
-
lb
|
- | |
03 | 2.7135: Install occupancy sensors | $415 | $1,056 |
$415
5,275
kWh
|
- | - | - | |
04 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $304 | $542 |
$451
6,741
kWh
|
$(-147.0)
-
MMBtu
|
- | - | |
05 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $269 | $395 |
$129
2,931
kWh
|
- | - | $140 | |
TOTAL RECOMMENDED | $8,291 | $5,465 |
$995
14,947
kWh
|
$2,068
-
MMBtu
|
$5,088
-
lb
|
$140 | ||
TOTAL IMPLEMENTED | $2,788 | $4,409 |
$580
9,672
kWh
|
$2,068
-
MMBtu
|
- | $140 |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs