Assessment Year 2019
Principal Product Water
NAICS 221310: Water Supply and Irrigation Systems
SIC 4941: Water Supply
Sales Range $10
M
to 50
M
# of Employees 23
Plant Area 1,045,440
ft2
Annual Production 1,700,000
Tgal
Production Hrs. Annual 8,760
hrs
Location (State) Texas

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $102,022 1,373,568
kWh
Electricity Demand $12,846 3,211
kW-mo/yr
Electricity Fees $(-12,971.4) -
TOTAL YEARLY COSTS $101,897
RECOMMENDED SAVINGS* $493,161 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* $3,577

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Water Usage Savings
01 2.7142: Utilize higher efficiency lamps and/or ballasts $1,893 $2,389 $1,893
22,645
kWh
-
02 2.7142: Utilize higher efficiency lamps and/or ballasts $2,060 $1,959 $2,060
24,642
kWh
-
03 2.7135: Install occupancy sensors $1,234 $616 $1,234
14,759
kWh
-
04 2.7232: Replace existing hvac unit with high efficiency model $1,095 $3,250 $1,095
13,097
kWh
-
05 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,388 - $1,388
16,606
kWh
-
06 3.7311: Maintain machines to reduce leaks $1,094 $844 - $1,094
-
Tgal
07 3.8121: Cover containers to minimize evaporative losses $483,876 $1,077,133 - $483,876
-
Tgal
08 2.7423: Reduce heat gain by window tinting $520 $483 $520
6,217
kWh
-
TOTAL RECOMMENDED $493,161 $1,086,674 $8,190
97,965
kWh
$484,971
-
Tgal
TOTAL IMPLEMENTED $3,577 $4,094 $2,483
29,703
kWh
$1,094
-
Tgal
Yearly Savings* Imp'd Cost* Electricity Usage Savings Water Usage Savings
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs