Assessment Year | 2017 |
---|---|
Principal Product | Blades, Nozzles, and Hangers |
NAICS | 336412: Aircraft Engine and Engine Parts Manufacturing |
SIC | 3724: Aircraft Engines and Engine Parts |
Sales Range | $1 M to 5M |
# of Employees | 500 |
Plant Area |
108,000
ft2
|
Annual Production | 200,000
pieces
|
Production Hrs. Annual | 8,544
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $605,704 | 18,643,402 |
kWh
|
$0.032 | |
Electricity Demand | $528,871 | 47,946 |
kW-mo/yr
|
$11.03 | |
Electricity Fees | $33,914 | - |
|
- | |
Natural Gas | $29,914 | 11,104 |
MMBtu
|
$2.69 | |
Waste Disposal Costs | |||||
Water Usage | $2,268 | 1,354 |
Tgal
|
$1.68 | |
Water Disposal | $33,059 | 1,176 |
Tgal
|
$28.11 | |
TOTAL YEARLY COSTS | $1,233,730 | ||||
RECOMMENDED SAVINGS* | $307,395 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $306,047 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $4,452 | $6,500 |
$4,452
140,229
kWh
|
- | - | - | |
02 | 2.2523: Reduce infiltration to refrigerated areas; isolate hot equipment from refrigerated areas | $1,056 | $417 |
$1,056
33,139
kWh
|
- | - | - | |
03 | 3.4146: Change method of deionized water production | $258,000 | $292,000 | - | - | - | $258,000 | |
04 | 3.4155: Meter waste water | $11,708 | $2,650 | - | - |
$11,708
-
Tgal
|
- | |
05 | 2.7111: Reduce illumination to minimum necessary levels | $15,338 | $56,000 | - |
$15,338
-
kW-mo/yr
|
- | - | |
06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $1,836 | $8,821 |
$1,836
57,816
kWh
|
- | - | - | |
07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $223 | $399 |
$223
7,008
kWh
|
- | - | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $287 | $494 |
$287
9,054
kWh
|
- | - | - | |
09 | 2.2522: Isolate hot or cold equipment | $292 | $1,422 |
$292
9,209
kWh
|
- | - | - | |
10 | 2.2521: Isolate steam lines to avoid heating air conditioned areas | $8,320 | $966 |
$8,320
262,056
kWh
|
- | - | - | |
11 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $5,882 | $25,954 |
$5,882
185,274
kWh
|
- | - | - | |
TOTAL RECOMMENDED | $307,395 | $395,623 |
$22,349
703,785
kWh
|
$15,338
-
kW-mo/yr
|
$11,708
-
Tgal
|
$258,000 | ||
TOTAL IMPLEMENTED | $306,047 | $393,784 |
$21,001
661,437
kWh
|
$15,338
-
kW-mo/yr
|
$11,708
-
Tgal
|
$258,000 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Water Disposal Savings | One-time Revenue or Avoided Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs