Assessment Year | 2017 |
---|---|
Principal Product | Valves |
NAICS | 332911: Industrial Valve Manufacturing |
SIC | 3491: Industrial Valves |
Sales Range | $1 M to 5M |
# of Employees | 113 |
Plant Area |
101,000
ft2
|
Annual Production | 50,000
units
|
Production Hrs. Annual | 2,016
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | ||
---|---|---|---|---|---|
Electricity Usage | $278,011 | 3,169,440 |
kWh
|
$0.088 | |
Electricity Demand | $3,191 | 968 |
kW-mo/yr
|
$3.30 | |
Natural Gas | $1,131 | 102 |
MMBtu
|
$11.09 | |
Waste Disposal Costs | |||||
Water Usage | $7,999 | 1,268,700 |
Tgal
|
$0.006 | |
TOTAL YEARLY COSTS | $290,332 | ||||
RECOMMENDED SAVINGS* | $56,304 |
See individual recommendations below
*Non-energy impacts included in savings.
|
|||
IMPLEMENTED SAVINGS* | $51,161 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|---|---|
01 | 2.8121: Apply for tax-free status for energy purchases | $19,042 | $5,000 | - | - | $19,042 | - | - | - | |
02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $6,935 | $23,676 |
$5,946
67,569
kWh
|
$989
-
kW-mo/yr
|
- | - | - | - | |
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $112 | - |
$112
1,277
kWh
|
- | - | - | - | - | |
04 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $441 | $237 |
$126
1,430
kWh
|
$7
-
kW-mo/yr
|
- | $72 | - | $237 | |
05 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $5,143 | $50 | - | - | - | - | $5,143 | - | |
06 | 2.7495: Install replacement doors | $9,766 | $5,000 |
$9,766
110,976
kWh
|
- | - | - | - | - | |
07 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $13,442 | $2,500 |
$11,522
130,928
kWh
|
$1,920
-
kW-mo/yr
|
- | - | - | - | |
08 | 2.7111: Reduce illumination to minimum necessary levels | $1,422 | $6 |
$1,220
13,860
kWh
|
$203
-
kW-mo/yr
|
- | - | - | - | |
TOTAL RECOMMENDED | $56,304 | $36,468 |
$28,691
326,039
kWh
|
$3,119
-
kW-mo/yr
|
$19,042 | $72 | $5,143 | $237 | ||
TOTAL IMPLEMENTED | $51,161 | $36,418 |
$28,691
326,039
kWh
|
$3,119
-
kW-mo/yr
|
$19,042 | $72 | - | $237 | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Administrative Changes Savings | Primary Raw Material Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs