| Assessment Year | 2000 |
|---|---|
| Principal Product | Cakes, Brownies, Buns, Rolls and Breads |
| NAICS |
n/a
|
| SIC | 2051: Bread and Other Bakery Products, Except Cookies and Crackers |
| Sales Range | $10 M to 50M |
| # of Employees | 200 |
| Plant Area |
n/a
|
| Annual Production | 200,000,000
pieces
|
| Production Hrs. Annual | 4,400
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $104,514 | 2,840,270 |
kWh
|
$0.037 |
| Electricity Demand | $37,676 | 5,651 |
kW-mo/yr
|
$6.67 |
| Natural Gas | $69,478 | 27,004 |
MMBtu
|
$2.57 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $13,220 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $9,309 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Water Consumption Savings |
|---|---|---|---|---|---|---|---|---|---|
| 01 | 2.1233: Analyze flue gas for proper air/fuel ratio | $4,906 | $600 | - | - |
$4,906
-
MMBtu
|
- | - | |
| 02 | 3.4116: Meter recycled water (to reduce sewer charges) | $2,404 | $6,200 | - | - | - | - |
$2,404
-
Tgal
|
|
| 03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,255 | $509 |
$1,650
52,462
kWh
|
$605
-
kW-mo/yr
|
- | - | - | |
| 04 | 4.821: Pay bills on time to avoid late fees | $1,092 | - | - | - | - | $1,092 | - | |
| 05 | 2.7124: Make a practice of turning off lights when not needed | $1,056 | - |
$1,056
33,411
kWh
|
- | - | - | - | |
| 06 | 2.4133: Use most efficient type of electric motors | $566 | $3,147 |
$214
8,792
kWh
|
$352
-
kW-mo/yr
|
- | - | - | |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $152 | $634 |
$116
3,810
kWh
|
$36
-
kW-mo/yr
|
- | - | - | |
| 08 | 2.7144: Install spectral reflectors / delamp | $455 | $84 | - |
$455
-
kW-mo/yr
|
- | - | - | |
| 09 | 2.2136: Install / repair insulation on steam lines | $334 | $301 | - | - |
$334
-
MMBtu
|
- | - | |
| TOTAL RECOMMENDED | $13,220 | $11,475 |
$3,036
98,475
kWh
|
$1,448
-
kW-mo/yr
|
$5,240
-
MMBtu
|
$1,092 |
$2,404
-
Tgal
|
||
| TOTAL IMPLEMENTED | $9,309 | $1,109 |
$2,706
85,873
kWh
|
$605
-
kW-mo/yr
|
$4,906
-
MMBtu
|
$1,092 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Administrative Changes Savings | Water Consumption Savings | |||