Assessment Year | 2000 |
---|---|
Principal Product | Metal Plant Hopers |
NAICS |
n/a
|
SIC | 3443: Fabricated Plate Work (Boiler Shops) |
Sales Range | $10 M to 50M |
# of Employees | 150 |
Plant Area |
n/a
|
Annual Production | 638
pieces
|
Production Hrs. Annual | 4,709
hrs
|
Location (State) | Texas |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $57,598 | 1,435,522 |
kWh
|
$0.040 |
Electricity Demand | $34,784 | 5,568 |
kW-mo/yr
|
$6.25 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $32,681 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | - |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings |
---|---|---|---|---|---|---|
01 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $19,884 | - | n/a | - |
$19,884
-
kW-mo/yr
|
02 | 2.3212: Optimize plant power factor | $992 | $1,750 | n/a | - |
$992
-
kW-mo/yr
|
03 | 2.7121: Utilize daylight whenever possible in lieu of artificial light | $4,665 | $9,759 | n/a |
$4,665
149,472
kWh
|
- |
04 | 2.7135: Install occupancy sensors | $3,468 | $1,720 | n/a |
$3,468
92,028
kWh
|
- |
05 | 2.7124: Make a practice of turning off lights when not needed | $1,241 | - | n/a |
$1,241
39,859
kWh
|
- |
06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $1,115 | $35 | n/a |
$707
22,567
kWh
|
$408
-
kW-mo/yr
|
07 | 2.7124: Make a practice of turning off lights when not needed | $550 | $176 | n/a |
$320
10,258
kWh
|
$230
-
kW-mo/yr
|
08 | 2.4133: Use most efficient type of electric motors | $430 | $1,186 | n/a |
$272
8,792
kWh
|
$158
-
kW-mo/yr
|
09 | 2.4314: Use synthetic lubricant | $218 | - | n/a |
$138
4,396
kWh
|
$80
-
kW-mo/yr
|
10 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $118 | $290 | n/a |
$73
2,052
kWh
|
$45
-
kW-mo/yr
|
TOTAL RECOMMENDED | $32,681 | $14,916 |
$10,884
329,424
kWh
|
$21,797
-
kW-mo/yr
|
||
TOTAL IMPLEMENTED | - | - | - | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs