| Assessment Year | 2000 |
|---|---|
| Principal Product | Beef and Chicken products |
| NAICS |
n/a
|
| SIC | 2013: Sausages and Other Prepared Meat Products |
| Sales Range | $10 M to 50M |
| # of Employees | 135 |
| Plant Area |
n/a
|
| Annual Production | 20,400,000
pieces
|
| Production Hrs. Annual | 4,080
hrs
|
| Location (State) | Texas |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $185,167 | 5,106,682 |
kWh
|
$0.036 |
| Electricity Demand | $12,189 | 4,052 |
kW-mo/yr
|
$3.01 |
| Natural Gas | $5,367 | 973 |
MMBtu
|
$5.52 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $23,855 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings |
|---|---|---|---|---|---|---|---|---|
| 01 | 3.1191: Change procedures / equipment / operating conditions | $9,563 | $3,724 | n/a | - | - | - |
$9,563
-
lb
|
| 02 | 3.1191: Change procedures / equipment / operating conditions | $10,633 | $2,612 | n/a | - | - | - |
$10,633
-
lb
|
| 03 | 2.4314: Use synthetic lubricant | $1,314 | - | n/a |
$502
22,274
kWh
|
$812
-
kW-mo/yr
|
- | - |
| 04 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $973 | $874 | n/a |
$373
16,706
kWh
|
$600
-
kW-mo/yr
|
- | - |
| 05 | 2.8112: Combine utility meters | $660 | $415 | n/a | - | - | $660 | - |
| 06 | 2.7135: Install occupancy sensors | $428 | $450 | n/a |
$428
19,050
kWh
|
- | - | - |
| 07 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $173 | $267 | n/a |
$99
4,396
kWh
|
$74
-
kW-mo/yr
|
- | - |
| 08 | 2.7131: Add area lighting switches | $111 | - | n/a |
$111
4,982
kWh
|
- | - | - |
| TOTAL RECOMMENDED | $23,855 | $8,342 |
$1,513
67,408
kWh
|
$1,486
-
kW-mo/yr
|
$660 |
$20,196
-
lb
|
||
| TOTAL IMPLEMENTED | - | - | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Electricity Fees Savings | Solid Waste (non-haz) Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs