| Assessment Year | 2000 |
|---|---|
| Principal Product | Small electric motors |
| NAICS |
n/a
|
| SIC | 3621: Motors and Generators |
| Sales Range | $5 M to 10M |
| # of Employees | 175 |
| Plant Area |
65,000
ft2
|
| Annual Production | 1,000,000
pieces
|
| Production Hrs. Annual | 4,000
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $69,818 | 1,944,607 |
kWh
|
$0.036 |
| Electricity Demand | $43,034 | 5,389 |
kW-mo/yr
|
$7.99 |
| Electricity Fees | $2,115 | - |
|
- |
| Natural Gas | $48,328 | 7,874 |
MMBtu
|
$6.14 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $134,115 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $67,600 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Gaseous Waste Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $37,600 | $7,800 | - | - | - |
$12,600
-
lb
|
- | - | - | $25,000 | |
| 02 | 4.321: Optimize production lot sizes and inventories | $30,000 | $26,000 | - | - | - | - | - | $30,000 | - | - | |
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $29,410 | $49,230 |
$23,340
359,027
kWh
|
$6,070
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 04 | 3.8121: Cover containers to minimize evaporative losses | $27,490 | $300 | - | - | - | - |
$27,490
-
lb
|
- | - | - | |
| 05 | 2.7144: Install spectral reflectors / delamp | $6,460 | $3,340 |
$6,170
94,959
kWh
|
- | - | - | - | - | $290 | - | |
| 06 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $2,650 | $215 |
$1,960
30,188
kWh
|
$690
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 07 | 2.2514: Cover open tanks | $505 | $800 | - | - |
$505
-
MMBtu
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $134,115 | $87,685 |
$31,470
484,174
kWh
|
$6,760
-
kW-mo/yr
|
$505
-
MMBtu
|
$12,600
-
lb
|
$27,490
-
lb
|
$30,000 | $290 | $25,000 | ||
| TOTAL IMPLEMENTED | $67,600 | $33,800 | - | - | - |
$12,600
-
lb
|
- | $30,000 | - | $25,000 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Solid Waste (non-haz) Savings | Gaseous Waste Savings | Administrative Changes Savings | Ancillary Material Cost Savings | By-product Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs