Assessment Year | 1999 |
---|---|
Principal Product | Polyester polymers and fibers |
NAICS |
n/a
|
SIC | 2824: Manmade Organic Fibers, Except Cellulosic |
Sales Range | $50 M to 100M |
# of Employees | 110 |
Plant Area |
3,764,300
ft2
|
Annual Production | 120,000,000
lb
|
Production Hrs. Annual | 8,736
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $1,261,890 | 46,339,098 |
kWh
|
$0.027 |
Electricity Demand | $750,022 | 75,849 |
kW-mo/yr
|
$9.89 |
Electricity Fees | $(-15,431.0) | - |
|
- |
Natural Gas | $223,557 | 58,441 |
MMBtu
|
$3.83 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $342,525 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $81,375 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Ancillary Material Cost Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|
01 | 2.1311: Replace electrically-operated equipment with fossil fuel equipment | $93,920 | $120,140 |
$90,010
3,913,541
kWh
|
$55,050
-
kW-mo/yr
|
$(-51,140.0)
-
MMBtu
|
- | - | - | - | |
02 | 2.7111: Reduce illumination to minimum necessary levels | $6,480 | $1,000 |
$4,020
174,678
kWh
|
$2,460
-
kW-mo/yr
|
- | - | - | - | - | |
03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $3,135 | $5,115 |
$1,415
61,547
kWh
|
$1,720
-
kW-mo/yr
|
- | - | - | - | - | |
04 | 3.1291: Eliminate practice of mixing waste streams | $78,240 | $6,600 | - | - | - |
$18,020
-
Tgal
|
$16,060
-
gal
|
$44,160 | - | |
05 | 2.4312: Improve lubrication practices | $48,250 | $111,600 |
$29,940
1,301,583
kWh
|
$18,310
-
kW-mo/yr
|
- | - | - | - | - | |
06 | 4.321: Optimize production lot sizes and inventories | $112,500 | $60,000 | - | - | - | - | - | - | $112,500 | |
TOTAL RECOMMENDED | $342,525 | $304,455 |
$125,385
5,451,349
kWh
|
$77,540
-
kW-mo/yr
|
$(-51,140.0)
-
MMBtu
|
$18,020
-
Tgal
|
$16,060
-
gal
|
$44,160 | $112,500 | ||
TOTAL IMPLEMENTED | $81,375 | $11,715 |
$1,415
61,547
kWh
|
$1,720
-
kW-mo/yr
|
- |
$18,020
-
Tgal
|
$16,060
-
gal
|
$44,160 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Water Disposal Savings | Other Liquid (non-haz) Savings | Ancillary Material Cost Savings | Primary Product Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs