| Assessment Year | 1998 |
|---|---|
| Principal Product | Sheet metal siding and roofing panels |
| NAICS |
n/a
|
| SIC | 3440: |
| Sales Range | $10 M to 50M |
| # of Employees | 35 |
| Plant Area |
12,000
ft2
|
| Annual Production | 22,000,000
lb
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $19,565 | 449,883 |
kWh
|
$0.043 |
| Electricity Demand | $8,863 | 1,466 |
kW-mo/yr
|
$6.05 |
| Electricity Fees | $424 | - |
|
- |
| Natural Gas | $6,314 | 8,246 |
MMBtu
|
$0.77 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $341,135 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $294,005 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings | By-product Production Savings | Increase in Production Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.1191: Change procedures / equipment / operating conditions | $177,600 | $510,000 | - | - |
$110,845
-
lb
|
- | - | - | - | $66,755 | |
| 02 | 4.421: Modify current incentive program | $81,550 | $16,885 | - | - | - | $19,140 | $(-106,760.0) | $169,170 | - | - | |
| 03 | 4.322: Eliminate old stock and modify inventory control | $45,000 | $26,000 | - | - | - | - | $45,000 | - | - | - | |
| 04 | 3.1192: Reduce scrap production | $33,515 | $24,000 | - | - |
$44,535
-
lb
|
- | $(-16,750.0) | $5,730 | - | - | |
| 05 | 3.5217: Reuse / recycle/ sell paper products | $2,130 | $1,200 | - | - | - | - | - | - | $2,130 | - | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $660 | $2,190 |
$310
9,379
kWh
|
$350
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 07 | 2.6212: Turn off equipment during breaks, reduce operating time | $300 | - |
$300
9,086
kWh
|
- | - | - | - | - | - | - | |
| 08 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $230 | $500 |
$110
3,224
kWh
|
$120
-
kW-mo/yr
|
- | - | - | - | - | - | |
| 09 | 2.4314: Use synthetic lubricant | $150 | - |
$30
879
kWh
|
$120
-
kW-mo/yr
|
- | - | - | - | - | - | |
| TOTAL RECOMMENDED | $341,135 | $580,775 |
$750
22,568
kWh
|
$590
-
kW-mo/yr
|
$155,380
-
lb
|
$19,140 | $(-78,510.0) | $174,900 | $2,130 | $66,755 | ||
| TOTAL IMPLEMENTED | $294,005 | $553,575 |
$750
22,568
kWh
|
$590
-
kW-mo/yr
|
$155,380
-
lb
|
$19,140 | $(-123,510.0) | $174,900 | - | $66,755 | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings | By-product Production Savings | Increase in Production Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs