Assessment Year | 1998 |
---|---|
Principal Product | Hydraulic cylinders |
NAICS |
n/a
|
SIC | 3593: Fluid Power Cylinders and Actuators |
Sales Range | $10 M to 50M |
# of Employees | 126 |
Plant Area |
62,000
ft2
|
Annual Production | 17,200
pieces
|
Production Hrs. Annual | 6,240
hrs
|
Location (State) | Virginia |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $29,804 | 1,414,127 |
kWh
|
$0.021 |
Electricity Demand | $31,254 | 3,624 |
kW-mo/yr
|
$8.62 |
Electricity Fees | $1,466 | - |
|
- |
Natural Gas | $14,691 | 2,256 |
MMBtu
|
$6.51 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $49,420 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $995 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Solid Waste (non-haz) Savings | Increase in Production Savings |
---|---|---|---|---|---|---|---|
01 | 4.514: Re-arrange equipment layout to reduce handling costs | $46,480 | $37,380 | - | - | $46,480 | |
02 | 3.6192: Use a less expensive method of waste removal | $1,455 | - | - |
$1,455
-
lb
|
- | |
03 | 2.2511: Insulate bare equipment | $670 | $220 |
$670
29,894
kWh
|
- | - | |
04 | 2.2437: Recover waste heat from equipment | $490 | $980 |
$490
21,981
kWh
|
- | - | |
05 | 3.6192: Use a less expensive method of waste removal | $175 | - | - |
$175
-
lb
|
- | |
06 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $150 | $600 |
$150
6,448
kWh
|
- | - | |
TOTAL RECOMMENDED | $49,420 | $39,180 |
$1,310
58,323
kWh
|
$1,630
-
lb
|
$46,480 | ||
TOTAL IMPLEMENTED | $995 | $820 |
$820
36,342
kWh
|
$175
-
lb
|
- | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Solid Waste (non-haz) Savings | Increase in Production Savings |