Assessment Year | 1997 |
---|---|
Principal Product | Ready-mix concrete plants |
NAICS |
n/a
|
SIC | 3564: Industrial and Commercial Fans and Blowers and Air Purification Equipment |
Sales Range | $10 M to 50M |
# of Employees | 95 |
Plant Area |
106,000
ft2
|
Annual Production | 50
pieces
|
Production Hrs. Annual | 3,025
hrs
|
Location (State) | Kentucky |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $35,347 | 837,339 |
kWh
|
$0.042 |
Electricity Demand | $18,627 | 2,930 |
kW-mo/yr
|
$6.36 |
Electricity Fees | $6,245 | - |
|
- |
Natural Gas | $20,305 | 4,429 |
MMBtu
|
$4.58 |
Other Energy | $850 | 134 |
MMBtu
|
$6.34 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $92,293 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $65,312 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Energy Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |
---|---|---|---|---|---|---|---|---|---|---|---|---|
01 | 3.5248: Separate and recycle scrap metal to foundry or for sale | $36,000 | - | - | - | - | - | - | - | $36,000 | - | |
02 | 4.111: Add equipment/ operators to reduce production bottleneck | $28,880 | $7,540 | - | - | - | - | - | $28,880 | - | - | |
03 | 2.7231: Use radiant heater for spot heating | $16,711 | $30,300 | - | - |
$15,861
-
MMBtu
|
$850
-
MMBtu
|
- | - | - | - | |
04 | 4.421: Modify current incentive program | $6,500 | $10,000 | - | - | - | - | - | - | - | $6,500 | |
05 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $3,770 | $10,800 | - | - | - | - |
$3,770
-
lb
|
- | - | - | |
06 | 2.4314: Use synthetic lubricant | $432 | - |
$111
3,810
kWh
|
$321
-
kW-mo/yr
|
- | - | - | - | - | - | |
TOTAL RECOMMENDED | $92,293 | $58,640 |
$111
3,810
kWh
|
$321
-
kW-mo/yr
|
$15,861
-
MMBtu
|
$850
-
MMBtu
|
$3,770
-
lb
|
$28,880 | $36,000 | $6,500 | ||
TOTAL IMPLEMENTED | $65,312 | $7,540 |
$111
3,810
kWh
|
$321
-
kW-mo/yr
|
- | - | - | $28,880 | $36,000 | - | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Other Energy Savings | Solid Waste (non-haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Product Savings |