| Assessment Year | 1996 |
|---|---|
| Principal Product | Hydraulic pumps |
| NAICS |
n/a
|
| SIC | 3561: Pumps and Pumping Equipment |
| Sales Range | $10 M to 50M |
| # of Employees | 98 |
| Plant Area |
73,000
ft2
|
| Annual Production | 20,000
pieces
|
| Production Hrs. Annual | 6,732
hrs
|
| Location (State) | Kentucky |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $172,533 | 4,730,950 |
kWh
|
$0.036 |
| Electricity Demand | $56,524 | 12,182 |
kW-mo/yr
|
$4.64 |
| Natural Gas | $8,063 | 1,488 |
MMBtu
|
$5.42 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $31,647 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $17,959 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 01 | 3.2121: Convert to electrostatic powder coating | $10,682 | $26,600 |
$(-500.0)
(-13,775)
kWh
|
- | - |
$2,000
-
lb
|
$5,606 | - | $3,576 | |
| 02 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $9,333 | $21,300 |
$7,607
211,313
kWh
|
$1,726
-
kW-mo/yr
|
- | - | - | - | - | |
| 03 | 2.6218: Turn off equipment when not in use | $4,500 | - |
$4,500
124,267
kWh
|
- | - | - | - | - | - | |
| 04 | 3.6193: Install equipment (eg compactor) to reduce disposal costs | $4,126 | $8,500 | - | - | - | - | - | $4,126 | - | |
| 05 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,359 | $2,300 |
$802
22,274
kWh
|
$557
-
kW-mo/yr
|
- | - | - | - | - | |
| 06 | 3.4115: Recover and reuse cooling water | $1,311 | $2,530 |
$(-100.0)
(-2,638)
kWh
|
- |
$862
-
gal
|
- | - | - | $549 | |
| 07 | 2.4314: Use synthetic lubricant | $336 | - |
$169
4,689
kWh
|
$167
-
kW-mo/yr
|
- | - | - | - | - | |
| TOTAL RECOMMENDED | $31,647 | $61,230 |
$12,478
346,130
kWh
|
$2,450
-
kW-mo/yr
|
$862
-
gal
|
$2,000
-
lb
|
$5,606 | $4,126 | $4,125 | ||
| TOTAL IMPLEMENTED | $17,959 | $29,800 |
$12,107
335,580
kWh
|
$1,726
-
kW-mo/yr
|
- | - | - | $4,126 | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Other Liquid (non-haz) Savings | Solid Waste (haz) Savings | Personnel Changes Savings | Administrative Changes Savings | Primary Raw Material Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs