Assessment Year | 1994 |
---|---|
Principal Product | Residential interior wooden doors |
NAICS |
n/a
|
SIC | 2431: Millwork |
Sales Range | $10 M to 50M |
# of Employees | 56 |
Plant Area |
78,000
ft2
|
Annual Production | 1,100,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Tennessee |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $30,531 | 533,705 |
kWh
|
$0.057 |
Natural Gas | $12,309 | 2,132 |
MMBtu
|
$5.77 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $189,045 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $121,441 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
---|---|---|---|---|---|---|---|
01 | 2.1321: Replace fossil fuel equipment with electrical equipment | $5,297 | $17,400 | - |
$5,297
-
MMBtu
|
- | |
02 | 2.4231: Reduce the pressure of compressed air to the minimum required | $2,314 | $490 |
$2,314
41,325
kWh
|
- | - | |
03 | 2.4236: Eliminate leaks in inert gas and compressed air lines/ valves | $952 | $300 |
$952
16,999
kWh
|
- | - | |
04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $624 | $440 |
$624
11,137
kWh
|
- | - | |
05 | 2.6218: Turn off equipment when not in use | $261 | - |
$261
4,689
kWh
|
- | - | |
06 | 3.1182: Make a new by-product | $118,866 | $206,400 | - | - |
$118,866
-
lb
|
|
07 | 3.1162: Use less wasteful packaging | $35,354 | $65,000 | - | - |
$35,354
-
lb
|
|
08 | 3.2123: Convert to high volume low pressure (hvlp) paint guns | $14,584 | $13,200 | - | - |
$14,584
-
lb
|
|
09 | 3.1191: Change procedures / equipment / operating conditions | $5,860 | - | - | - |
$5,860
-
lb
|
|
10 | 3.5315: Lease / purchase baler; sell cardboard to recycler | $4,933 | $8,480 | - | - |
$4,933
-
lb
|
|
TOTAL RECOMMENDED | $189,045 | $311,710 |
$4,151
74,150
kWh
|
$5,297
-
MMBtu
|
$179,597
-
lb
|
||
TOTAL IMPLEMENTED | $121,441 | $206,890 |
$2,575
46,014
kWh
|
- |
$118,866
-
lb
|
||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Natural Gas Savings | Solid Waste (non-haz) Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs