| Assessment Year | 1994 |
|---|---|
| Principal Product | Industrial Thread |
| NAICS |
n/a
|
| SIC | 2284: Thread Mills |
| Sales Range | $10 M to 50M |
| # of Employees | 350 |
| Plant Area |
235,000
ft2
|
| Annual Production | 10,000,000
lb
|
| Production Hrs. Annual | 8,400
hrs
|
| Location (State) | North Carolina |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $1,843,952 | 39,128,078 |
kWh
|
$0.047 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $125,038 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.7144: Install spectral reflectors / delamp | $64,659 | $115,952 | n/a |
$64,659
1,225,088
kWh
|
| 02 | 2.6127: Maintain air filters by cleaning or replacement | $24,016 | - | n/a |
$24,016
541,618
kWh
|
| 03 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $11,557 | $7,667 | n/a |
$11,557
245,897
kWh
|
| 04 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $8,554 | $2,285 | n/a |
$8,554
182,005
kWh
|
| 05 | 2.7124: Make a practice of turning off lights when not needed | $6,734 | - | n/a |
$6,734
143,318
kWh
|
| 06 | 2.7111: Reduce illumination to minimum necessary levels | $3,664 | $480 | n/a |
$3,664
77,960
kWh
|
| 07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $3,278 | $4,000 | n/a |
$3,278
69,754
kWh
|
| 08 | 2.7124: Make a practice of turning off lights when not needed | $2,576 | $1,040 | n/a |
$2,576
54,807
kWh
|
| TOTAL RECOMMENDED | $125,038 | $131,424 |
$125,038
2,540,447
kWh
|
||
| TOTAL IMPLEMENTED | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs