| Assessment Year | 1993 |
|---|---|
| Principal Product | Round and square logs for log home c |
| NAICS |
n/a
|
| SIC | 2491: Wood Preserving |
| Sales Range | $5 M to 10M |
| # of Employees | 60 |
| Plant Area |
20,000
ft2
|
| Annual Production | 250
pieces
|
| Production Hrs. Annual | 2,475
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $86,465 | 674,385 |
kWh
|
$0.13 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $37,228 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $2,019 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings |
|---|---|---|---|---|---|
| 01 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $1,905 | $1,320 |
$1,905
14,654
kWh
|
|
| 02 | 2.6212: Turn off equipment during breaks, reduce operating time | $610 | $1,010 |
$610
4,689
kWh
|
|
| 03 | 2.4231: Reduce the pressure of compressed air to the minimum required | $419 | - |
$419
3,224
kWh
|
|
| 04 | 2.4314: Use synthetic lubricant | $114 | - |
$114
879
kWh
|
|
| 05 | 2.3212: Optimize plant power factor | $25,200 | $8,300 |
$25,200
-
kWh
|
|
| 06 | 2.3131: Reschedule plant operations or reduce load to avoid peaks | $8,980 | - |
$8,980
-
kWh
|
|
| TOTAL RECOMMENDED | $37,228 | $10,630 |
$37,228
23,446
kWh
|
||
| TOTAL IMPLEMENTED | $2,019 | $1,320 |
$2,019
15,533
kWh
|
||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs