| Assessment Year | 1992 |
|---|---|
| Principal Product | LAMINATED PLASTIC FURN. |
| NAICS |
n/a
|
| SIC | 2541: Wood Office and Store Fixtures, Partitions, Shelving, and Lockers |
| Sales Range | $1 M to 5M |
| # of Employees | 30 |
| Plant Area |
n/a
|
| Annual Production | 8,000
pieces
|
| Production Hrs. Annual | 2,080
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $13,669 | 200,469 |
kWh
|
$0.068 |
| Natural Gas | $8,410 | 1,252 |
MMBtu
|
$6.72 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $4,351 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | - | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Administrative Changes Savings |
|---|---|---|---|---|---|---|
| 01 | 2.7123: Keep lamps and reflectors clean | $2,859 | $8,652 |
$2,710
39,859
kWh
|
$149 | |
| 02 | 2.7221: Lower temperature during the winter season and vice-versa | $817 | - |
$817
18,171
kWh
|
- | |
| 03 | 2.4111: Utilize energy-efficient belts and other improved mechanisms | $259 | $85 |
$259
3,810
kWh
|
- | |
| 04 | 2.6212: Turn off equipment during breaks, reduce operating time | $219 | $350 |
$219
3,224
kWh
|
- | |
| 05 | 2.4231: Reduce the pressure of compressed air to the minimum required | $140 | - |
$140
2,052
kWh
|
- | |
| 06 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $57 | $114 |
$291
4,396
kWh
|
$(-234.0) | |
| TOTAL RECOMMENDED | $4,351 | $9,201 |
$4,436
71,512
kWh
|
$(-85.0) | ||
| TOTAL IMPLEMENTED | - | - | - | - | ||
| Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Administrative Changes Savings | |||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs