Assessment Year | 2001 |
---|---|
Principal Product | greeting cards |
NAICS |
n/a
|
SIC | 2771: Greeting Cards |
Sales Range | $10 M to 50M |
# of Employees | 230 |
Plant Area |
160,000
ft2
|
Annual Production | 50,000,000
pieces
|
Production Hrs. Annual | 4,420
hrs
|
Location (State) | Colorado |
Facility Energy Cost and Usage
Source | Yearly Cost | Usage | Unit Cost | |
---|---|---|---|---|
Electricity Usage | $38,405 | 2,194,696 |
kWh
|
$0.017 |
Electricity Demand | $93,078 | 6,732 |
kW-mo/yr
|
$13.83 |
Electricity Fees | $1,076 | - |
|
- |
Natural Gas | $19,413 | 4,034 |
MMBtu
|
$4.81 |
TOTAL YEARLY COSTS | - | |||
RECOMMENDED SAVINGS* | $12,300 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
IMPLEMENTED SAVINGS* | $3,650 |
Recommendations
# | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
---|---|---|---|---|---|---|---|---|
01 | 2.3191: Use demand controller or load shedder | $4,830 | $8,000 | - |
$4,830
-
kW-mo/yr
|
- | - | |
02 | 2.4146: Use adjustable frequency drive or multiple speed motors on existing system | $2,250 | $12,950 |
$2,250
137,400
kWh
|
- | - | - | |
03 | 2.7221: Lower temperature during the winter season and vice-versa | $1,810 | $1,470 | - | - |
$1,810
-
MMBtu
|
- | |
04 | 2.7224: Reduce space conditioning during non-working hours | $1,810 | $3,750 | - | - |
$1,810
-
MMBtu
|
- | |
05 | 2.2211: Use optimum temperature | $610 | $200 |
$130
7,800
kWh
|
$480
-
kW-mo/yr
|
- | - | |
06 | 2.2211: Use optimum temperature | $500 | - |
$100
5,900
kWh
|
$400
-
kW-mo/yr
|
- | - | |
07 | 2.4231: Reduce the pressure of compressed air to the minimum required | $460 | $60 |
$140
8,700
kWh
|
$320
-
kW-mo/yr
|
- | - | |
08 | 2.7142: Utilize higher efficiency lamps and/or ballasts | $30 | - |
$40
2,300
kWh
|
$140
-
kW-mo/yr
|
- | $(-150.0) | |
TOTAL RECOMMENDED | $12,300 | $26,430 |
$2,660
162,100
kWh
|
$6,170
-
kW-mo/yr
|
$3,620
-
MMBtu
|
$(-150.0) | ||
TOTAL IMPLEMENTED | $3,650 | $5,220 |
$40
2,300
kWh
|
$140
-
kW-mo/yr
|
$3,620
-
MMBtu
|
$(-150.0) | ||
Yearly Savings* | Imp'd Cost* | Electricity Usage Savings | Electricity Demand Savings | Natural Gas Savings | Ancillary Material Cost Savings |
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs