ITAC Assessment: TN0458
ITAC logo
ITAC Assessment: TN0458
Grant Funding Opportunity NOW OPEN
Up to $300k at 50% cost share for qualifying* projects.
Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received an ITAC, Onsite Energy/CHP TAP, or qualified equivalent assessment since 2018 can now apply for grants for implementation of assessment recommendations at up to 50% of qualifying* project costs with a maximum of $300,000 per grant.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
Assessment Year 1992
Principal Product BATTERIES
NAICS
n/a
SIC 3691: Storage Batteries
Sales Range $100
M
to 500
M
# of Employees 250
Plant Area
n/a
Annual Production 250,000,000
pieces
Production Hrs. Annual 5,760
hrs
Location (State) Tennessee

Facility Energy Cost and Usage

Source Yearly Cost Usage
Electricity Usage $744,578 14,622,216
kWh
Natural Gas $78,896 15,998
MMBtu
TOTAL YEARLY COSTS -
RECOMMENDED SAVINGS* $11,230 *Non-energy impacts included in savings.
IMPLEMENTED SAVINGS* -

Recommendations

# Description Yearly Savings* Imp'd Cost* Status Electricity Usage Savings Natural Gas Savings
01 2.1212: Operate boilers on high fire setting $4,410 $15,000 - $4,410
-
MMBtu
02 2.4221: Install compressor air intakes in coolest locations $4,619 $570 $4,619
90,563
kWh
-
03 2.4111: Utilize energy-efficient belts and other improved mechanisms $1,853 $3,390 $1,853
36,342
kWh
-
04 2.2511: Insulate bare equipment $348 $25 - $348
-
MMBtu
TOTAL RECOMMENDED $11,230 $18,985 $6,472
126,905
kWh
$4,758
-
MMBtu
TOTAL IMPLEMENTED - - - -
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs