| Assessment Year | 1990 |
|---|---|
| Principal Product | CONCRETE REINFORCING BAR |
| NAICS |
n/a
|
| SIC | 3312: Steel Works, Blast Furnaces (Including Coke Ovens), and Rolling Mills |
| Sales Range | $50 M to 100M |
| # of Employees | 250 |
| Plant Area |
n/a
|
| Annual Production | 250,000
ton
|
| Production Hrs. Annual | 6,120
hrs
|
| Location (State) | Tennessee |
Facility Energy Cost and Usage
| Source | Yearly Cost | Usage | Unit Cost | |
|---|---|---|---|---|
| Electricity Usage | $6,222,035 | 163,665,888 |
kWh
|
$0.038 |
| Natural Gas | $1,563,832 | 510,950 |
MMBtu
|
$3.06 |
| TOTAL YEARLY COSTS | - | |||
| RECOMMENDED SAVINGS* | $588,183 |
See individual recommendations below
*Non-energy impacts included in savings.
|
||
| IMPLEMENTED SAVINGS* | $142,051 | |||
Recommendations
| # | Description | Yearly Savings* | Imp'd Cost* | Status | Electricity Usage Savings | Natural Gas Savings |
|---|---|---|---|---|---|---|
| 01 | 2.6212: Turn off equipment during breaks, reduce operating time | $52,799 | $3,900 | - |
$52,799
-
MMBtu
|
|
| 02 | 2.2424: Use heat in flue gases to preheat products or materials | $446,132 | $265,300 |
$446,132
11,740,328
kWh
|
- | |
| 03 | 2.6212: Turn off equipment during breaks, reduce operating time | $52,799 | - | - |
$52,799
-
MMBtu
|
|
| 04 | 2.2531: Re-size charging openings or add movable cover or door | $36,453 | $12,800 | - |
$36,453
-
MMBtu
|
|
| TOTAL RECOMMENDED | $588,183 | $282,000 |
$446,132
11,740,328
kWh
|
$142,051
-
MMBtu
|
||
| TOTAL IMPLEMENTED | $142,051 | $16,700 | - |
$142,051
-
MMBtu
|
||
*Savings and costs are best estimates based on the center's site visit, associated engineering analysis, and typical capital and labor costs